Part Number: 6598170121
98 EP CORE SET
EP designs reduce the effect of residual air gap upon the effective permeability of the core, hence they minimize coil volume for a given inductance. EP cores also provide a high degree of isolation from adjacent components and are advantageously used in low power devices, matching and broadband transformers.
EP cores can be supplied with the center post gapped to a mechanical dimension or an ALvalue.
Weight indicates is per pair or set.
Weight: 6 (g)
Dim | mm | mm tol | nominal inch | inch misc. |
A | 18.1 | ± 0.40 | 0.713 | _ |
B | 8.4 | ± 0.40 | 0.331 | _ |
C | 11 | ± 0.30 | 0.433 | _ |
D | 5.7 | ± 0.20 | 0.224 | _ |
E | 12 | ± 0.40 | 0.472 | _ |
F | 5.7 | ± 0.20 | 0.224 | _ |
K | 3.45 | min | 0.135 | _ |
Chart Legend
Σl/A : Core Constant, le : Effective Path Length, Ae : Effective Cross-Sectional Area, Ve : Effective Core Volume
AL : Inductance Factor
Explanation of Part Numbers: Digits 1 & 2 = product class and 3 & 4 = material grade.
Electrical Properties | |
AL(nH) | 2300 ±25% |
Ae(cm2) | 0.336 |
Σl/A(cm-1) | 8 |
le(cm) | 2.68 |
Ve(cm3) | 0.899 |
Amin(cm2) | 0.252 |
AL value is measured at 1 kHz, B < 10 gauss