Chart Legend
+ Test frequency
•For solid cable cores, see Round Cable EMI Suppression Cores
| Typical Impedance (Ω) |
| 100 MHz+ | 100 Min. |
| 250 MHz | 175 Min. |
| Electrical Properties |
| Ae(cm²) | 1.27 |
| Σl/A(cm⁻¹) | 0.0583 |
| le(cm) | 7.41 |
| Ve(cm³) | 9.41 |
Oval Cable Clip-It assemblies are controlled for impedances only. Minimum impedance values are specified for the + marked frequencies. The minimum impedance is typically the listed impedance less 20%.
Single turn impedance tests for 31, 43 and 46 material cores are performed on the E4991A/HP4291B Impedance Analyzer. The 61 material parts are tested on the E4991A / HP4291B Impedance Analyzer and 75 material parts are tested on the E4990A Impedance Analyzer. Cores are tested with the shortest practical wire length.
| Typical Impendance (Ω) |
|
|
|
|
| 100 MHz+ |
100 |
| 250 MHz |
175 |